DLX-FL vertical electric suction type self cleaning filter strainer for industrial

Application: Circulating cooling water ; Waste water treatment; Membrane protection.

Product structure

1515031296641107.jpg




        1.Electirc motor
        2.Drain valve
        3.Screen
        4.Suction nozzle
        5.Water inlet
        6.Water outlet








Principle

The water flows through the screen and the particles are retained on the inside of the screen of the filter element. The filtered water then flows out through the outlet.

Self-cleaning mode can be started by pressing, timing or manual three ways, following the principle of pressure difference.

When the internal and external pressure difference reaches the set value,  the self-cleaning mode starts.Drain pipe hydraulic valve open, sucking the scanner to produce negative pressure suction nozzle inside, absorbing impurities, at the same time sucking scanner in under hydraulic motor along the inside surface mesh do reciprocating screw, movement, no cleaning blind area, impurities by the discharge outlet.

The cleaning time of self-cleaning filter is set by the controller in advance, the drain valve is closed after cleaning, and little water loss in cleaning process.


Technical Parameters
■ Single maximum filtration flow up to 4000m3 / h
Filter optional drilling (4000-800μm), wedge (1000-50μm) woven composite (800-20μm)
minimum working pressure ≥ 0.1Mpa (sewage valve for the electric ball valve)
≥0.18Mpa (discharge valve for the electromagnetic diaphragm valve)
Maximum working pressure ≤ 1.6MPa (special customizable)
Operating temperature ≤ 95 ℃
■ Water quality turbidity ≤ 60mg / L
(A short period of time to allow to 110mg / L, if the high turbidity is too long, it is recommended to pre-pretreatment)
■ Power: 380V / 50Hz
■ Control voltage: AC24V
■ Cleaning method: suction type
■ Cleaning time: 10-200 seconds adjustable
■ Control: pressure, time, manual and PLC
 

FL Series Self-cleaning filter technical data sheet

自清洗DLX-FL尺寸图_1.jpg

Model

Water

 in/outlet

(mm)

A
(mm)
B
(mm)
C
(mm)
D
(mm)
E
(mm)
F
(mm)
Power
(KW)
Max flow
(m3/h)
Weight
(Kg)
DLX-FL-5050240250117756034012770.251950
DLX-FL-6565240250117756034012770.253070
DLX-FL-8080240250117756034012770.255080
DLX-FL-100100240400142756034015270.2580105
DLX-FL-150150240490155756034016600.25150180
DLX-FL-200200285685205756037722600.25320235
DLX-FL-250250333745227058342625500.25490280
DLX-FL-300300395830244563553030950.25710420


Loss of pressure table

DLX-FL.jpg